Smith & Nephew TRIVEX™ System Surgical Illuminator REF 7210351, handheld transillumination probe for powered phlebectomy, stainless housing, CE 0123 marked, compatible with TRIVEX console assemblies

$50.00

1 in stock

Smith & Nephew TRIVEX™ System Surgical Illuminator REF 7210351, handheld transillumination probe for powered phlebectomy, stainless housing, CE 0123 marked, compatible with TRIVEX console assemblies

Condition: Used, great condition. Professionally cleaned; normal cosmetic wear from prior use. Unit is engraved: “REF 7210351”, “SN YN0997”, “US PATENT 5,893,858”, “CE 0123”, and “TRIVEX SYSTEM Illuminator”. No original packaging, accessories, or sterile barrier included.

The Smith & Nephew TRIVEX™ Surgical Illuminator (REF 7210351) is a reusable handheld light probe designed to provide bright, focused transillumination during TRIVEX procedures (transilluminated powered phlebectomy) and related venous surgery. In use, the illuminator is inserted through a small incision to flood the subcutaneous plane with light, enhancing visualization of superficial varicosities while the powered resector addresses targeted tissue. Its compact, robust construction suits operating-room handling and repeated reprocessing when performed per the manufacturer’s IFU. The CE 0123 mark indicates conformity under the notified body 0123 (TÜV SÜD). The engraved U.S. Patent No. 5,893,858 corresponds to technology used in transillumination-assisted venous procedures.

Important: This listing is for the Illuminator instrument only. It requires compatible TRIVEX system components (light source/console, fiber/light cable, and standard surgical accessories) to operate. Item is supplied non-sterile and must be cleaned and sterilized according to the official Instructions for Use (IFU) before clinical use.

Features

  • Handheld transillumination probe engineered for the Smith & Nephew TRIVEX™ system
  • Bright, directed illumination to enhance visualization of subcutaneous anatomy during venous procedures
  • Reusable instrument; supports repeated reprocessing when performed strictly per manufacturer IFU
  • Stainless/metallic housing with OR-friendly ergonomics and engraved identifiers for asset tracking
  • CE 0123 marking for conformity assessment within the EU/UK (per applicable regulations at time of manufacture)
  • Patent reference (US 5,893,858) engraved—corresponds to transillumination surgical technique
  • Designed to integrate with TRIVEX light/console assemblies via the specified light/fiber interface
  • Low-profile form factor supports small-incision access and atraumatic handling

Applications / Spheres of Application

  • Vascular surgery / Phlebology: transilluminated powered phlebectomy (TRIVEX™ technique)
  • General/Plastic surgery: illumination-assisted subcutaneous procedures where enhanced visualization is beneficial (per surgeon judgment)
  • Teaching environments: demonstration of transillumination anatomy and technique on venous cases

Cross-Referenced Models (Smith & Nephew TRIVEX family)

(Related or system-mate components; verify REF and compatibility.)

  • REF 7210351 – TRIVEX Surgical Illuminator (this item)
  • TRIVEX Resection Handpiece / Powered Resection Unit (use alongside the illuminator; model varies by generation)
  • TRIVEX Light/Console Assembly (required for illumination output; model/REF varies)
  • TRIVEX Tumescence Infiltration components (adjunct instruments; model/REF varies)

Cross-references are provided for system context. Always match REF numbers, connection interfaces, and IFU requirements before combining components.

Comparable Products (functional role; other manufacturers)

(For buyers evaluating alternatives with similar clinical purpose; confirm regulatory status, interfaces, and IFU.)

  • Transillumination probes used in vein surgery from other vascular platforms (model-specific)
  • Illuminating cannulas / lighted retractors providing subcutaneous transillumination (various brands)
  • Endoscopic lighted dissectors for illumination of the subdermal plane (procedure- and brand-specific)

Integration & System Use

  • System role: Provides the lighted visualization component of the Smith & Nephew TRIVEX™ technique.
  • Required mates (not included): Compatible TRIVEX light source/console, appropriate fiber/light cable, and the powered resector and tubing as specified by Smith & Nephew’s IFU.
  • Sterilization: Device must be cleaned and sterilized per the manufacturer IFU prior to use. Confirm allowable sterilization cycles and parameters (e.g., steam autoclave, temperature limits).
  • Inspection: Prior to any use, inspect lens, distal tip, and connector interface for damage, discoloration, or debris.
  • Regulatory markers: CE 0123 (TÜV SÜD) engraved; users are responsible for ensuring ongoing regulatory compliance in their jurisdiction and facility.

Identification & Serialization

  • REF (Catalog Number): 7210351
  • SN (Serial Number): YN0997 (format observed on engraving; manufacturer-specific coding—may indicate internal batch/sequence. Production date decoding is not confirmed here.)
  • Markings on instrument: “REF 7210351”, “SN YN0997”, “US PATENT 5,893,858”, “CE 0123”, “TRIVEX SYSTEM Illuminator”
  • UPC/GTIN: Not provided on this unit

What’s Included

  • Smith & Nephew TRIVEX™ System Surgical Illuminator, REF 7210351 (single instrument)
  • No light source, cables, sterilization tray, drapes, or accessories included

Related

Smith & Nephew TRIVEX illuminator; TRIVEX light probe; surgical transillumination instrument; venous surgery lighted cannula; varicose vein removal illuminator; powered phlebectomy illumination; OR transillumination device; device to illuminate subcutaneous tissue; vascular surgery accessory; CE 0123 surgical instrument; light probe for TRIVEX; surgical illuminator handpiece

Common Requests:

  1. “Is the REF 7210351 TRIVEX illuminator compatible with my existing Smith & Nephew TRIVEX console and fiber cable?”
  2. “What sterilization cycles are approved for the TRIVEX Surgical Illuminator (steam parameters and cycle limits)?”
  3. “Can I use this illuminator with third-party light sources or must it be Smith & Nephew only?”
  4. “What inspection/maintenance steps are recommended before and after each case for REF 7210351?”
  5. “Does REF 7210351 include the resector or is it strictly the illumination component for TRIVEX procedures?”

Manufacturer Trademarks Disclaimer: Smith & Nephew and TRIVEX are trademarks of Smith & Nephew plc or its affiliates. Any other brand or product names mentioned are the property of their respective owners. Use of these names is for identification and compatibility reference only and does not imply endorsement.

 

P123

Weight 1 lbs
Dimensions 14 × 3 × 2 in

Reviews

There are no reviews yet.

Be the first to review “Smith & Nephew TRIVEX™ System Surgical Illuminator REF 7210351, handheld transillumination probe for powered phlebectomy, stainless housing, CE 0123 marked, compatible with TRIVEX console assemblies”
Product added!
The product is already in the wishlist!
Removed from Wishlist