Carrier CAOVRFLW001A00 Condensate Drain Trap Accessory Kit – 6 to 30 Ton Units
$65.00
1 in stock
Carrier CAOVRFLW001A00 Condensate Drain Trap Accessory Kit – 6 to 30 Ton Units
Condition: New.
The Carrier CAOVRFLW001A00 Condensate Drain Trap Accessory Kit is a versatile and essential accessory designed for Carrier 6 to 30 ton packaged air handling units. This adjustable drain trap ensures efficient condensate management, preventing overflow and maintaining optimal system performance. It can be installed in both vertical (upflow) and horizontal configurations, providing flexibility for various installations. The kit also includes an integrated overflow shutoff switch, which can be wired to shut down the system or trigger an alarm if a blockage occurs. For easy maintenance, the transparent trap body allows for visual inspection, and a flexible cleaning brush is included.
Features
Model: CAOVRFLW001A00
Manufacturer: Carrier
Type: Condensate Drain Trap Accessory Kit
Compatibility: Carrier 6 to 30 Ton Packaged Air Handling Units
Installation Configuration: Vertical (Upflow) or Horizontal
Integrated Overflow Switch:
Automatically shuts down the system if the drain trap is blocked
Can be connected to an alarm using the included wire harness
Visual Inspection: Transparent trap body allows easy blockage detection
Easy Maintenance: Includes a flexible cleaning brush for routine cleaning
Adjustable Design: Customizable to various installation setups
Corrosion-Resistant Materials: Durable for long-term use in HVAC applications
Wiring Harness Included: Simplifies connection to unit control system
Applications
Commercial HVAC Systems: Ideal for Carrier 6 to 30 ton packaged air handling units in commercial buildings.
Residential Multi-Zone Systems: Ensures reliable condensate management in larger systems.
Industrial HVAC Systems: Suitable for use in factories, warehouses, and other industrial facilities.
Data Centers: Prevents overflow and water damage in critical cooling environments.
Medical Facilities: Maintains safe and efficient HVAC operation in hospitals and clinics.
Cross-Referenced Models
Carrier CAOVRFLW002A00 (Larger Capacity Model)
Carrier CRTAP001 (Standard Condensate Trap without Overflow Protection)
Carrier 30RAP Condensate Trap Kit (Compatible with Certain Packaged Units)
Comparable Products
Trane CNT07761 Condensate Drain Trap Kit (6-20 Ton Units)
Lennox 19W08 Condensate Drain Kit (Horizontal/Vertical Configuration)
Goodman CTK01A Condensate Overflow Protection Kit
Rectorseal EZ-Trap 83132 (Universal Drain Trap with Overflow Protection)
Assembly & System Use
Installation Instructions:
Determine Installation Configuration: Select vertical (upflow) or horizontal based on your unit setup.
Mount the Trap: Secure the trap to the drain pan outlet using the appropriate fittings.
Connect Overflow Switch:
Wire the switch to the unit’s control system (shutdown function).
Use the included harness to connect an optional alarm.
Test the System: Verify that the overflow switch functions correctly (system shuts off if trap is blocked).
Maintenance: Use the included cleaning brush to clear debris from the trap periodically.
Maintenance Tips:
Inspect the transparent trap body for blockages during routine service.
Use the flexible cleaning brush to clear any visible debris.
Test the overflow switch regularly to ensure reliable operation.
Related
Carrier condensate drain trap
adjustable condensate trap for HVAC
overflow protection drain trap
Carrier 6 to 30 ton air handler accessories
condensate trap with integrated float switch
Carrier CAOVRFLW001A00 replacement
Common Requests:
-Can this trap be used with other brands of air handling units?
It is specifically designed for Carrier 6 to 30 ton units. Compatibility with other brands may vary.
-How does the overflow switch work?
If the trap becomes blocked, the switch will open the circuit, shutting down the unit or triggering an alarm.
-Is this trap required for horizontal installations?
Yes, the adjustable design allows it to function in both horizontal and vertical setups.
-Can the overflow switch be bypassed?
It is not recommended, as this would disable the overflow protection feature.
-How often should the trap be cleaned?
Inspect and clean the trap at least once per cooling season or more frequently in high-humidity environments.
All product names, trademarks, and registered trademarks are the property of their respective owners. Use of these names does not imply any affiliation or endorsement.
P116
Weight | 3 lbs |
---|---|
Dimensions | 14 × 11 × 4 in |
You must be logged in to post a review.
Reviews
There are no reviews yet.